Starting up fieldbus communication and programming the ABB PLC (one-drive system)
73
Add function block MC_Reset
This function block makes the transition from state ErrorStop to STANDSTILL by
resetting all internal axis-related errors. It does not affect the output of the function
block instances.
Class: VAR, Type: MC_Reset. Add global variable reset_axis1 for switching
purposes, because the reset block cannot be active constantly,
Class: VAR_GLOBAL, Type: BOOL.
Add function block MC_Power
This function block controls the power stage on or off.
Class: VAR, Type: MC_Power. Add global variables enable_axis1 and
power_status_axis1 for start-up and visualization, Class: VAR_GLOBAL, Type:
BOOL.
Tool/Step
Programming the PLC main program